Sistema de análise em fluxo contínuo, empregando lã de PET, para determinação de selênio em amostras de alimentos

dc.contributor.advisorLuccas, Pedro Orival
dc.contributor.authorAlmeida, Mariana Aparecida dos Santos Silva de
dc.contributor.refereeLima, Giovana de Fátima
dc.contributor.refereeSilva, Julio Cesar Jose da
dc.date.accessioned2026-02-19T20:07:22Z
dc.date.available2026-02-19T20:07:22Z
dc.date.issued2025-08-27
dc.description.abstractO selênio, mineral essencial com origem em processos naturais e atividades humanas, é crucial para a saúde, mas exige consumo moderado, sendo 400 mg a dose máxima diária recomendada para adultos. Seu desequilíbrio, seja por excesso ou deficiência, está associado a disfunções em sistemas vitais, o que justifica o monitoramento rigoroso em amostras alimentares. No contexto da determinação de elementos traços, para as técnicas analíticas que não possuem detectabilidade adequada, recursos adicionais, como SPE são valiosas para melhorar o desempenho. O presente estudo apresenta uma abordagem simples, ecológica e econômica para a extração de selênio (Se) em amostras de alimentos onde avaliou-se a lã de PET (Polietileno Tereftalato) como adsorvente em SPE, essa lã é composta 100% de poliéster. O sistema proposto para pré-concentração e determinação de selênio é baseado em análise em fluxo contínuo FIA com Espectrometria de Absorção Atômica com Chama (FIA-FAAS). O sistema FIA-SPE-FAAS foi otimizado com ferramentas quimiométricas de planejamento fatorial de AA, CAA, CE e VP, e subsequente matriz de Doehlert com três variáveis sendo AA, CAA e CE e as condições obtidas foram [H+] = 1,0 x 10-2 , a vazão de eluição de 5,0 mL min-1, o eluente utilizado para dessorção foi KMnO4 0,07 mol L-1. Obteve-se uma faixa de resposta linear entre 8,28 e 200 µg L-1 (r = 0.9905), fator de pré-concentração de 73, LD 2,48µg L-1 e LQ 8,28 µg L-1. O método proposto possui uma boa precisão com desvio padrão relativo (RDS) < 5%, a exatidão foi avaliada através de testes de adição e recuperação após a digestão ácida nos quais variaram entre 93,46 e 96,66%. A metodologia foi aplicada com eficiência na determinação em amostras de água de coco comerciais. Trata-se de uma alternativa de baixo custo, rápida e com precisão e exatidão adequadas para o monitoramento de teores de selênio.
dc.description.abstract2Selenium, an essential mineral originating from natural processes and human activities, is crucial for health, but requires moderate consumption, with 400 mg being the maximum recommended daily dose for adults. Its imbalance, whether due to excess or deficiency, is associated with dysfunctions in vital systems, which justifies rigorous monitoring in food samples. In the context of trace element determination, for analytical techniques that lack adequate detectability, additional resources such as SPE are valuable for improving performance. This study presents a simple, ecological, and economical approach for the extraction of selenium (Se) in food samples, where PET (Polyethylene Terephthalate) wool was evaluated as an adsorbent in SPE; this wool is composed of 100% polyester. The proposed system for pre-concentration and determination of selenium is based on continuous flow analysis (FIA) with Flame Atomic Absorption Spectrometry (FIA-FAAS). The FIA-SPE- FAAS system was optimized with chemometric tools of factorial design for AA, CAA, CE and VP, and subsequent Doehlert matrix with three variables being AA, CAA and CE, and the conditions obtained were [H+] = 1.0 x 10-2, the elution flow rate of 5.0 mL min-1, and the eluent used for desorption was 0.07 mol L-1 KMnO4. A linear response range between 8.28 and 200 µg L⁻¹ (r = 0.9905) was obtained, with a preconcentration factor of 73, LOD of 2.48 µg L⁻¹, and LOQ of 8.28 µg L⁻¹. The proposed method exhibits good precision with a relative standard deviation (RSD) < 5%, and accuracy was evaluated through addition and recovery tests after acid digestion, which ranged between 93,46 and 96,66%. The methodology was efficiently applied to the determination of selenium levels in commercial coconut water samples. It is a low-cost, fast, and accurate alternative suitable for monitoring selenium levels.
dc.description.additionalinformationTermo SEI 1602676 CRC24C36201
dc.description.physical51
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior – CAPES
dc.identifier.credential2022.2.202.005
dc.identifier.lattesAdvisor3672437413599685
dc.identifier.lattesAuthor8525043835229154
dc.identifier.urihttps://repositorio.unifal-mg.edu.br/handle/123456789/3311
dc.language.isopt
dc.publisher.campiSede
dc.publisher.courseMestrado em Química
dc.publisher.departmentInstituto de Química
dc.publisher.initialsUNIFAL-MG
dc.publisher.institutionUniversidade Federal de Alfenas
dc.publisher.programPrograma de Pós-Graduação em Química
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject.cnpqCiências Exatas e da Terra
dc.subject.enSelenium
dc.subject.enFIA-FAAS system
dc.subject.pt-BRSelênio
dc.subject.pt-BRSistema FIA-FAAS
dc.subject.pt-BRLã de PET (fibras de poliéster)
dc.subject.pt-BRPET wool (polyester fibers)
dc.titleSistema de análise em fluxo contínuo, empregando lã de PET, para determinação de selênio em amostras de alimentos
dc.typeinfo:eu-repo/semantics/masterThesis

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Dissertacao de Mariana Aparecida dos Santos Silva de Almeida.pdf
Tamanho:
1.75 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.89 KB
Formato:
Item-specific license agreed upon to submission
Descrição: